Ducted fan coil

Ducted fan coil

  • Airflow Capacity: 800–2,100 CFM
  • Coil: 4-row coil with 5/8-inch copper tubes
  • Casing: 1.25 mm galvanized steel sheet
  • Fan Motor: Single-phase, three-speed fan
  • Installation Configuration: Available with front or bottom air discharge and rear or bottom air intake, depending on the selected configuration.

Description

Form Dama Ducted Fan Coil | Technical Specifications, Performance and Applications

The Form Dama Ducted Fan Coil is designed for heating and cooling applications in residential, commercial, and industrial buildings where conditioned air must be distributed through a ductwork system. Available in 7 models with airflow capacities ranging from 800 to 2,100 CFM, this unit offers different airflow options to accommodate a variety of HVAC project requirements.

The unit features a 4-row heat exchanger coil with 5/8-inch copper tubing, a die-cast aluminum structural frame reinforced with polyamide corners, and a galvanized steel casing with a thickness of 1.25 mm and an electrostatic paint finish. A single-phase, three-speed fan provides selectable operating speeds, while the washable aluminum filter supports routine maintenance.

To accommodate different installation layouts, Form Dama ducted fan coils can be configured with front or bottom air discharge and rear or bottom air intake, according to the selected model and project requirements.

What Is a Ducted Fan Coil?

A ducted fan coil is a hydronic HVAC terminal unit that conditions air by passing it across a water coil and distributing the resulting air through connected ducts.

During cooling operation, chilled water circulates through the coil and absorbs heat from the air passing over its surface. During heating operation, hot water transfers heat to the incoming air. The conditioned air is then supplied to the designated rooms or zones through the duct network.

The unit’s performance depends on several interacting factors, including airflow rate, coil characteristics, water temperature, water flow rate, entering air conditions, and the external static pressure imposed by the duct system.

Unlike a fan coil that discharges air directly into the room, a ducted fan coil is intended for integration with a duct distribution system. This makes it suitable for projects requiring concealed installation and air delivery through multiple outlets, subject to the system design.

Technical Specifications of Form Dama Ducted Fan Coil

The main specifications provided for Form Dama ducted fan coil units are summarized below.

Technical Parameter Specification
Product type Ducted fan coil
Number of models 7
Airflow capacity range 800–2,100 CFM
Heat exchanger coil 4-row
Copper tube size 5/8 inch
Fan type Single-phase, three-speed
Structural frame Die-cast aluminum
Frame reinforcement Polyamide corners
Casing material Galvanized steel sheet
Casing thickness 1.25 mm
Casing finish Electrostatic paint
Air filter Washable aluminum
Air discharge configuration Front or bottom
Air intake configuration Rear or bottom
Collector Integrated, high-strength design

Note: Model-specific cooling and heating capacities, external static pressure ratings, water flow rates, electrical power consumption, and sound levels should be confirmed through the manufacturer’s technical documentation.

Key Technical Features of Form Dama Ducted Fan Coil

1. Airflow Capacity from 800 to 2,100 CFM

Form Dama ducted fan coils are available in seven models covering an airflow range of 800 to 2,100 cubic feet per minute (CFM).

Airflow capacity describes the volume of air delivered by the unit over a given period. It is a key parameter in ducted HVAC design because it affects air distribution, room temperature control, and the ability of the system to meet its intended ventilation and conditioning requirements.

The appropriate model should be selected according to the calculated heating and cooling loads, required supply airflow, duct pressure losses, and the performance characteristics of the fan.

The stated CFM range should not be interpreted as the cooling or heating capacity of the unit. Thermal capacity must be evaluated separately under defined operating conditions.

2. Four-Row Coil with 5/8-Inch Copper Tubing

The unit incorporates a four-row heat exchanger coil constructed with 5/8-inch copper tubing.

The coil transfers heat between the circulating water and the air stream. Its performance depends on the coil geometry, heat-transfer surface, water flow rate, entering air temperature, air humidity, and water temperature.

The four-row configuration provides multiple rows of heat-transfer tubing within the air path. However, the number of rows alone does not establish the unit’s rated cooling or heating output. Model-specific performance data are required for accurate equipment selection.

3. Die-Cast Aluminum Frame with Reinforced Polyamide Corners

The structural frame uses die-cast aluminum components connected with reinforced polyamide corners.

This construction provides structural support for the unit assembly. The strength and stability of the frame are important for maintaining component alignment during installation and operation.

The installation design should also account for the unit’s weight, mounting arrangement, vibration control, and access requirements.

4. Galvanized Steel Casing with Electrostatic Paint

The casing is manufactured from 1.25 mm galvanized steel sheet and finished with electrostatic paint.

The galvanized steel provides the casing structure, while the coating adds a protective finish. The suitability of the casing for a particular installation also depends on the ambient environment, exposure to moisture, maintenance practices, and installation conditions.

5. Single-Phase, Three-Speed Fan

The fan operates on a single-phase electrical supply and provides three selectable speeds.

Changing the fan speed can alter the airflow delivered by the unit and influence its operating noise and electrical consumption. The actual airflow at each speed depends on the fan characteristics and the resistance of the connected ductwork.

The selected operating speed should therefore be checked against the required airflow and the system’s external static pressure. Exact fan curves and pressure ratings should be obtained from the applicable technical datasheet.

6. Configurable Air Intake and Discharge

Form Dama ducted fan coils can be ordered with different air intake and discharge arrangements to suit the project layout.

Available configurations include:

  • Front air discharge
  • Bottom air discharge
  • Rear air intake
  • Bottom air intake

These options help coordinate the unit with the duct connections and available installation space. The required arrangement should be specified before ordering because the final configuration must match the planned duct layout and equipment orientation.

Incorrectly planned intake or discharge connections can create unnecessary pressure losses, restrict airflow, or complicate maintenance access.

7. Washable Aluminum Air Filter

The unit includes a washable aluminum filter positioned in the air intake path.

The filter helps capture dust and airborne particles before they reach internal components. Regular cleaning is important because accumulated dust increases airflow resistance and may reduce the amount of air delivered through the duct system.

The filter should be inspected and cleaned according to the operating environment and the manufacturer’s maintenance recommendations. The filter is not, by itself, a substitute for a dedicated high-efficiency air purification system.

8. Integrated High-Strength Collector

The unit incorporates an integrated, high-strength collector as part of its construction.

The collector’s precise hydraulic arrangement and rated operating limits should be verified against the manufacturer’s technical drawings. Proper connection and support of the water circuit are important for reliable operation and serviceability.

How to Select the Correct Ducted Fan Coil

Selecting a ducted fan coil requires more than matching the nominal airflow range to the size of a room. The unit must meet the project’s thermal requirements while delivering the required airflow against the resistance of the duct system.

The following parameters should be evaluated during equipment selection.

Cooling and heating load: Calculate the design cooling and heating loads using the building envelope, occupancy, solar gains, internal heat sources, outdoor design conditions, and intended indoor conditions.

Required airflow: Determine the airflow needed to meet the thermal load and air distribution requirements. The appropriate value should be checked against the unit’s performance data.

External static pressure: Calculate the pressure losses through the ductwork, fittings, dampers, filters, grilles, and other connected components. Confirm that the selected fan can deliver the required airflow at the calculated operating pressure.

Water-side conditions: Verify chilled- and hot-water temperatures, available water flow rate, pipe connections, and the hydraulic requirements of the selected coil.

Air intake and discharge orientation: Confirm whether the project requires rear or bottom intake and front or bottom discharge.

Electrical requirements: Verify the motor’s rated voltage, frequency, current, and other electrical specifications using the applicable manufacturer’s documentation.

Installation and maintenance access: Allow adequate space for filter removal, inspection, cleaning, and access to serviceable components.

A suitable selection must satisfy both the required thermal output and the required airflow at the actual system operating conditions.

Applications of Form Dama Ducted Fan Coil

The Form Dama ducted fan coil can be considered for a range of HVAC projects, including:

  • Residential apartments and villas
  • Office buildings
  • Commercial buildings and retail spaces
  • Hotels and accommodation facilities
  • Large halls and shared indoor spaces
  • Industrial buildings requiring conditioned air
  • Multi-room buildings with ducted air distribution

The suitability of a specific model depends on the calculated load, duct configuration, operating conditions, and project design requirements.

Installation Considerations

Correct installation is essential for achieving the intended airflow and thermal performance.

Before installation, the project team should verify the unit’s orientation, duct connection dimensions, mounting support, water piping arrangement, electrical supply, and maintenance clearance.

The duct system should be designed to limit unnecessary pressure losses and distribute air appropriately across the connected outlets. Flexible connections, vibration isolation, and suitable support arrangements should be considered where required by the project design.

During cooling operation, condensate may form on the coil. The installation must therefore include a suitable condensate collection and drainage arrangement compatible with the unit design.

The water circuit should be connected and commissioned in accordance with the manufacturer’s instructions. Air trapped in the hydronic circuit, inadequate water flow, or unsuitable water temperatures may affect heat transfer and system performance.

Maintenance Requirements

Routine maintenance helps preserve airflow and supports reliable operation over the service life of the unit.

Recommended maintenance activities include:

  • Inspecting and cleaning the washable aluminum filter
  • Checking the coil for dust accumulation and restricted airflow
  • Inspecting the fan and motor for abnormal noise or vibration
  • Checking electrical connections in accordance with applicable safety procedures
  • Inspecting water connections for leakage
  • Verifying condensate drainage during cooling operation
  • Checking mounting supports and accessible structural components

Maintenance frequency should be based on operating hours, indoor air quality, environmental conditions, and the manufacturer’s recommendations. Electrical servicing should be performed by qualified personnel after the equipment has been safely isolated from the power supply.

Why Choose Form Dama Ducted Fan Coil?

Form Dama ducted fan coils combine a range of airflow options with a four-row copper-tube coil, a reinforced structural frame, a galvanized steel casing, and a washable aluminum filter.

The availability of seven models with airflow capacities from 800 to 2,100 CFM provides flexibility when matching the equipment to different ducted HVAC applications. Configurable intake and discharge arrangements also allow the installation layout to be considered during equipment selection.

For engineering projects, the final model should be selected using verified thermal performance, fan pressure characteristics, water-side requirements, electrical data, and the intended duct configuration.

Technical FAQs About Form Dama Ducted Fan Coil

1. What is the airflow capacity of Form Dama ducted fan coil units?

Form Dama ducted fan coils are available in seven models with airflow capacities ranging from 800 to 2,100 CFM. The required model should be selected based on the calculated thermal load, required airflow, and duct system resistance.

2. What is the difference between CFM and cooling capacity?

CFM measures the volume of air delivered per minute, whereas cooling capacity measures the rate at which heat is removed from a space. These parameters are related but are not interchangeable. A unit’s cooling capacity cannot be determined from its CFM rating alone.

3. What type of coil is used in Form Dama ducted fan coils?

The units feature a four-row coil with 5/8-inch copper tubing. The coil transfers heat between the circulating water and the air stream. Actual thermal performance depends on the water and air operating conditions and the detailed coil design.

4. Does a four-row coil guarantee a specific cooling capacity?

No. The number of coil rows is only one of several factors affecting heat transfer. Rated cooling and heating capacities also depend on coil surface area, water flow rate, entering air conditions, water temperature, and airflow. The manufacturer’s performance tables should be used to establish the capacity of each model.

5. What does the three-speed fan control?

The three-speed fan allows the unit to operate at different fan speeds. Each speed can produce a different airflow and operating condition. The delivered airflow must be verified against the fan performance data and the external static pressure of the connected ductwork.

6. Why must external static pressure be considered when selecting a ducted fan coil?

External static pressure represents the resistance the fan must overcome to move air through the connected duct system and accessories. If the resistance is too high for the selected fan operating point, the delivered airflow may fall below the required level. Proper selection requires matching the fan’s performance curve to the calculated system resistance.

7. What external static pressure can Form Dama ducted fan coils handle?

The available product information specifies an airflow range of 800–2,100 CFM but does not provide model-specific external static pressure ratings. These values should be obtained from the manufacturer’s technical datasheet before finalizing the fan coil selection.

8. Can the air intake and discharge directions be selected according to the project?

Yes. The available configurations include rear or bottom air intake and front or bottom air discharge. The required arrangement should be confirmed when ordering to ensure that the unit matches the duct layout and installation space.

9. What is the purpose of the washable aluminum filter?

The filter helps capture dust and airborne particles entering the unit. Regular cleaning helps prevent excessive airflow resistance and supports consistent airflow through the coil. Cleaning intervals depend on the operating environment and should follow the manufacturer’s recommendations.

10. How does water flow rate affect the performance of a ducted fan coil?

Water flow rate affects the heat transferred between the coil and the air. Insufficient flow or unsuitable water temperatures may reduce the available cooling or heating output. The required flow rate should be determined from the selected model’s performance data and the design conditions of the hydronic system.

11. Can the same ducted fan coil provide both cooling and heating?

A hydronic fan coil can provide cooling when supplied with chilled water and heating when supplied with hot water, provided that the unit and the connected water system are configured for the required operating mode. The available water temperatures, piping arrangement, and control strategy must be verified for the project.

12. What electrical information should be checked before installation?

The electrical supply must be compatible with the motor’s rated voltage, frequency, current, and phase. Although the fan is specified as single-phase, three-speed, the exact electrical ratings should be confirmed from the technical documentation for the selected model.

13. Why is condensate drainage important?

During cooling, moisture from the air can condense on the cold coil surface. If condensate is not collected and drained correctly, water leakage or moisture-related problems may occur. Drainage should be installed in accordance with the unit design and the manufacturer’s instructions.

14. How should a ducted fan coil be sized for a commercial or industrial project?

Sizing should begin with a heating and cooling load calculation. The designer should then establish the required airflow, determine duct pressure losses, verify the available fan performance, and check the coil’s thermal output under the project’s water and air conditions. The selected model must meet all these requirements rather than relying on floor area or nominal CFM alone.

15. What causes insufficient airflow from a ducted fan coil?

Potential causes include a dirty filter, excessive duct resistance, restricted intake or discharge paths, unsuitable fan speed, or a fan operating point that does not match the system requirements. Diagnosis should include checking the filter, duct layout, air outlets, fan operation, and actual static pressure.

16. What causes insufficient cooling or heating from a ducted fan coil?

Possible causes include inadequate water flow, unsuitable chilled- or hot-water temperatures, a dirty coil, insufficient airflow, or an incorrect equipment selection for the calculated thermal load. A systematic inspection of the air side, water side, and operating conditions is necessary to identify the cause.

17. What maintenance is required for Form Dama ducted fan coils?

Maintenance includes cleaning the washable aluminum filter, inspecting the coil and fan, checking electrical components, examining water connections, and verifying condensate drainage. Inspection intervals should reflect operating conditions and the manufacturer’s maintenance recommendations.

18. What information is needed to select the correct Form Dama ducted fan coil?

The main requirements include the calculated cooling and heating loads, required airflow, duct layout and pressure losses, chilled- and hot-water conditions, electrical supply, intake and discharge orientation, and available installation space. The selected model’s technical data should then be checked against these requirements.

19. Are the cooling and heating capacities the same for all seven models?

No. The seven models cover an airflow range of 800–2,100 CFM, but the available information does not specify the thermal capacity of each model. Cooling and heating ratings should be confirmed individually under the manufacturer’s stated test conditions.

20. How can the price of a Form Dama ducted fan coil be determined?

Pricing depends on the selected model, its specifications, and the required configuration. To obtain an accurate quotation, provide the project requirements and preferred intake and discharge arrangement to Form Dama’s sales or technical team.

Conclusion

The Form Dama Ducted Fan Coil is designed for ducted HVAC applications requiring controlled air distribution and hydronic heating or cooling. Its seven-model range, 800–2,100 CFM airflow capacity, four-row coil with 5/8-inch copper tubing, reinforced aluminum frame, galvanized steel casing, three-speed fan, and washable aluminum filter provide key selection parameters for HVAC designers and project engineers.

For accurate equipment selection, airflow must be assessed together with external static pressure, thermal load, water-side operating conditions, electrical requirements, and duct configuration. Reviewing the technical data for the specific model is essential before finalizing a design or placing an order.

Contact Form Dama for model-specific technical information, equipment selection assistance, and a project quotation.

Reviews

There are no reviews yet.

Be the first to review “Ducted fan coil”

Your email address will not be published. Required fields are marked *

Similar products

Check the best products related to this product.

ثبت سفارش

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

    City

    post